Sign In | Join Free | My burrillandco.com
Home > Wireless I O Module >

4 Channels Analog I O Module Wireless Analog Inputs 4-20mA / 0-5V Wireless Transmission 2km

Shenzhen Qianhai Lensen Technology Co., Ltd
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap 4 Channels Analog I O Module Wireless Analog Inputs 4-20mA / 0-5V Wireless Transmission 2km from wholesalers
     
    Buy cheap 4 Channels Analog I O Module Wireless Analog Inputs 4-20mA / 0-5V Wireless Transmission 2km from wholesalers
    • Buy cheap 4 Channels Analog I O Module Wireless Analog Inputs 4-20mA / 0-5V Wireless Transmission 2km from wholesalers
    • Buy cheap 4 Channels Analog I O Module Wireless Analog Inputs 4-20mA / 0-5V Wireless Transmission 2km from wholesalers
    • Buy cheap 4 Channels Analog I O Module Wireless Analog Inputs 4-20mA / 0-5V Wireless Transmission 2km from wholesalers
    • Buy cheap 4 Channels Analog I O Module Wireless Analog Inputs 4-20mA / 0-5V Wireless Transmission 2km from wholesalers
    • Buy cheap 4 Channels Analog I O Module Wireless Analog Inputs 4-20mA / 0-5V Wireless Transmission 2km from wholesalers

    4 Channels Analog I O Module Wireless Analog Inputs 4-20mA / 0-5V Wireless Transmission 2km

    Ask Lasest Price
    Brand Name : Lensen
    Model Number : LS-RAI04
    Price : Negotiation
    Payment Terms : T/T, Western Union
    Supply Ability : 6000pcs/month
    Delivery Time : 2-7days
    • Product Details
    • Company Profile

    4 Channels Analog I O Module Wireless Analog Inputs 4-20mA / 0-5V Wireless Transmission 2km

    LS-RAI04 wireless analog acquisition module

    LS-RAI04 Modbus RTU is a 1W I/O module, 4 analog inputs, 1 RS485 (wireless RS485 customizes). Wireless control 2km-3km. Use for sensor data wireless collection.

    Character:
    Transparent I/O System
    Not need internet, no third party cell, no monthly fees
    You have full control over your own carrier
    Real time status feedback from the remote site
    Fast installation and easy setup


    Paramaeter

    Frequency433MHz or 450MHz or 470MHz
    Power output1W
    Products4AI
    Input type4-20mA or 0-5V or 0-10V
    Output type4-20mA or 0-5V or 0-10V
    Resolution ratio24 bit
    Accuracy±0.02%
    Power supply9-36V DC usually use 24V DC
    InterfaceRS-485
    Channel No.15ch default, can program via DIP switch
    AntennaSucker antenna with 1.5m cable
    Working temperature-35 °C~+75 °C industrial
    Working humidity10%-90% relative humidity, no condensation
    Dimension115×90×40(mm)
    Fix wayStandard 3.5 inch industrial DIN guild rail


    Advantage of wireless solution
    - No wires to bury or maintain, no need to drill holes on wall
    - Reliable communication in all direction,any terrain, regardless of hills, walls, trees
    - Cost saving in installation and maintenance
    - Radio/Lora based, no need internet and monthly fee, full ownership of the system
    - 4G based, high speed, no distance limit

    Lensen Wireless RTU features
    - Portable device, DIN-rail mounting for easy installation
    - Isolated inputs
    - LEDs for power supply, communication, input, output status
    - Flexible networking, point to point or point to multipoints
    - DIP to change different modes
    - Different types of I/O, DI, DO, AI, AO are available
    - I/O expandable
    - Short delay time
    - Easy handing on RS485 network, support Modbus RTU protocol
    - Support on-line upgrade. Can configure by customer in setting mode


    Modbus RTU communication and corresponding value

    Register types:

    Register typesRead command

    Write command
    (Control command)

    Power offFunction
    Hold register0x01

    Input --not support
    Output--support

    Not keepCan read input value
    0x03


    A. Hold register
    1. Analog input value: 0x0008~0x000B
    2. Analog output value: 0x0048~0x004B

    B: How to read
    Hold register: can read 4 analog input or control 4 analog output at one time

    Register control way

    AI/AOIC

    Read/
    write

    Function IDitems support
    No.IC TypePLC IDModbus ID
    AI1Hold register400098Read032AI/4AI
    AI2Hold register400109Read03
    AI3Hold register4001110Read034AI
    AI4Hold register4001211Read03
    AO1Hold register4007372Read/write03/062AO/4AO
    AO2Hold register4007473Read/write03/06
    AO3Hold register4007574Read/write03/064AO
    AO4Hold register4007675Read/write03/06


    About value calculation

    Analog input
    Our analog module’s max measure range value is : 0X7FFF
    1. Directly measure current and voltage
    Exact value=value you read/0x7FFF*max range
    For example: to read the 1st passage of module’s (with max range of 0-20mA) input value
    Register 0x0008(analog input of the 1st passage)
    Feedback: 0x3801
    Current value: (0x3801/0x7FFF)*20mA=8.7509mA

    2. To measure sensor’s value(4-20mA, 0-6 meter level sensor)
    If feedback value is less than 6554, level value is 0
    If feedback value is bigger than 6554, level value=(value read-6554)/(32767-6554)*measure ranges
    For example: feedback value is 0X3801, then corresponding level value is: ((0X3801-6554)/26213)*6 meter=1.7815 meter

    Analog output
    Analog module’s max measure range is: 0x7FFF
    Directly control output current and voltage
    Write register value=current or voltage value/measure range*0x7FFF
    For example: to control the 1st passage of analog module whose max measure range is 0-20mA
    Register 0x0048 (analog output of the 1st passage)
    To write register value:(8.75/20mA)*0X7FFF =14336=0x3800









    Product Tags:

    remote i o module

      

    remote io system

      
    Quality 4 Channels Analog I O Module Wireless Analog Inputs 4-20mA / 0-5V Wireless Transmission 2km for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Shenzhen Qianhai Lensen Technology Co., Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Find Similar Products By Category: