Sign In | Join Free | My burrillandco.com
Home > Wireless Modbus RTU >

8DI8DO Wireless Modbus RTU Wireless Pump Control 8 Inputs / Outputs White Plastic Enclosure

Shenzhen Qianhai Lensen Technology Co., Ltd
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap 8DI8DO Wireless Modbus RTU Wireless Pump Control 8 Inputs / Outputs White Plastic Enclosure from wholesalers
     
    Buy cheap 8DI8DO Wireless Modbus RTU Wireless Pump Control 8 Inputs / Outputs White Plastic Enclosure from wholesalers
    • Buy cheap 8DI8DO Wireless Modbus RTU Wireless Pump Control 8 Inputs / Outputs White Plastic Enclosure from wholesalers
    • Buy cheap 8DI8DO Wireless Modbus RTU Wireless Pump Control 8 Inputs / Outputs White Plastic Enclosure from wholesalers
    • Buy cheap 8DI8DO Wireless Modbus RTU Wireless Pump Control 8 Inputs / Outputs White Plastic Enclosure from wholesalers
    • Buy cheap 8DI8DO Wireless Modbus RTU Wireless Pump Control 8 Inputs / Outputs White Plastic Enclosure from wholesalers

    8DI8DO Wireless Modbus RTU Wireless Pump Control 8 Inputs / Outputs White Plastic Enclosure

    Ask Lasest Price
    Brand Name : Lensen
    Model Number : LS-RDIO0808
    Price : Negotiation
    Payment Terms : T/T, Western Union
    Supply Ability : 6000pcs/month
    Delivery Time : 2-7 days
    • Product Details
    • Company Profile

    8DI8DO Wireless Modbus RTU Wireless Pump Control 8 Inputs / Outputs White Plastic Enclosure

    8DI8DO Wireless Modbus RTU Wireless Pump Control 8 Inputs / Outputs White Plastic Enclosure


    1. LS-RDIO series module general introduction
    LS-RDIO Modbus RTU is an industrial controller designed by Lensen Technology. It supports point to point, point to multi-points wireless DI, DO, AI, AO collection and control. This transceiver has the advantage of easy installation, no program required, no communication fee. It is reliable and cost-effective substitution for rail signal cable, slip ring signal wire.

    This series we have 2DI/2DO module, 4DI/4DO module, 8DI/8DO module. Power output we have 2 versions, one is 100mW for 600m LOS control distance, and another one is 1W for 3km LOS control distance.


    2. Application Field
    LS-RDIO series I/O module is widely used in industry automation like factory central data process, pump control, oil monitoring, mining machinery, environment monitoring equipments, lifting devices, robots control, filling machine, mixing equipments, logistic line, AGV etc.


    3. Parameter

    Parameter
    Power output:1W or 100mW version
    Power supply:9V-30V (usually choose 24V DC or 12V DC)
    Control distance:3km or (1km version)
    Baud rate:1200bps
    Receiving sensibility:-123dBm@1200bps, -118dbm(9600bps)
    Networking
    Networking:Point to point and point to multipoint
    Port Description
    Input:8 active DI (passive customized)
    Output:

    8 relay passive outputs,
    contact max load AC250V/5A,DC30V/5A
    (Active output 0-5V customized)

    Communication portRS485 (wireless RS485 customize)
    Current
    Transmit current:<600mA (or 100mA version)
    Receiving current:<50mA (or 20mA version)
    General
    Frequency:433MHz, 400, 450, 470 or other band
    Channel No:16 channels,can change via DIP switch
    Physical Properties
    Dimension:145×90×40(mm)
    Antenna Connector:SMA,vehicle antenna with 1.5m cable
    Temperature:-35℃~+75℃( industrial)
    Mounting method:Standard 3.5 inch industrial guild rail

    4. How to use wireless I/O


    5. Application diagram examples

    1) Point to point control



    Remarks:

    Module AModule BInput and Output Correspondence
    A(DI1-DI8)B(DO1-DO8)DI1-DI8 of A to control DO1-DO8 of B respectively
    A(DO1-DO8)B(DI1-DI8)DO1-DO8 of A is controlled by DI1-DI8 of B respectively
    Notes: A and B should use the same channel



    2) One master to control 2 slaves

    Remarks:

    Master ModuleSlave ModuleInput and Output Correspondence
    A(DI1-DI4)B1(DO1-DO4)DI1-DI4 of A control DO1-DO4 of B1 respectively
    A(DI5-DI8)B2(DO1-DO4)DI5-DI8 of A control DO1-DO4 of B2 respectively
    A(DO1-DO4)B1(DI1-DI4)DO1-DO4 of A is controlled by DI1-DI4 of B1
    A(DO5-DO8)B2(DI1-DI4)DO5-DO8 of A is controlled by DI1-DI4 of B2
    Notes: A and B should use the same channel



    3) One master to control 4 slaves

    Remarks:

    MasterSlaveInput and Output Correspondence
    A(DI1-DI2)B1(DO1-DO2)DI1-DI2 of A control DO1-DO2 of B1
    A(DI3-DI4)B2(DO1-DO2)DI3-DI4 of A control DO1-DO2 of B2
    A(DI5-DI6)B3(DO1-DO2)DI5-DI6 of A control DO1-DO2 of B3
    A(DI7-DI8)B4(DO1-DO2)DI7-DI8 of A control DO1-DO2 of B4
    A(DO1-DO2)B1(DI1-DI2)DO1-DO2 of A controlled by DI1-DI2 of B
    A(DO3-DO4)B2(DI1-DI2)DO3-DO4 of A controlled by DI1-DI2 of B2
    A(DO5-DO6)B3(DI1-DI2)DO5-DO6 of A controlled by DI1-DI2 of B3
    A(DO7-DO8)B4(DI1-DI2)DO7-DO8 of A controlled by DI1-DI2 of B4
    Notes: A and B should use the same channel


    4) One master to 8 salves

    Remarks:

    MasterSalveInput and control correspondence
    A(DI1)B1(DO1)DI1 of A control DO1 of B1
    A(DI2)B2(DO1)DI2 of A control DO1 of B2
    A(DI3)B3(DO1)DI3 of A control DO1 of B3
    A(DI4)B4(DO1)DI4of A control DO1 of B4
    A(DI5)B5(DO1)DI5 of A control DO1 of B5
    A(DI6)B6(DO1)DI6 of A control DO1 of B6
    A(DI7)B7(DO1)DI7 of A control DO1 of B7
    A(DI8)B8(DO1)DI8 of A control DO1 of B8
    A(DO1)B1(DI1)DO1 of A is controlled by DI1 of B1
    A(DO8)B8(DI1)DO8 of A is controlled by DI1 of B8
    Note: module A and B should use the same channel;



    5) To communicate with PC/PLC